T15 Explosion Proof RTD Thermometer, US Style

Brand: Endress+Hauser

T15 Explosion Proof RTD Thermometer, US Style

Brand: Endress+Hauser
Extended Extended

The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.

The T15 temperature sensor is a RTD assembly designed for use in harsh environments and explosive areas, due to his FM and CSA approvals.

The sensor is made up of a measurement probe with an insulated RTD element and sheath.

The sensor assembly can be used in process industries such as:

  • Chemicals
  • Petrochemical
  • Refineries
  • Offshore Platforms
Features
  • FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety
  • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications
  • Remove and install straight out of the box!
  • Improved galvanic isolation on most devices (2 kV)
  • Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor, thermowell and transmitter assembly for a complete point solution
  • All iTEMP transmitters provide long term stability ≤0.05% per year

Specifications

Measuring Principle

  • Resistance Temperature Detector

Characteristic / Application

  • Explosion Proof US style modular temperature assembly for heavy duty applications with extension to be used with existing thermowell

Thermowell / Protection Tube

  • to be used with thermowell

Insert / Probe

  • mineral insulated (MI), flexible
  • PTFE-insulated, rigid

Outer Diameter Protection Tube / Insert

  • Not applicable

Max. Immersion Length on Request

  • up to 100" (2540 mm)
  • others on request

Material Protection Tube/ Thermowell

  • Sensor sheath
  • 316/316L

Optional Coating

  • Not defined

Process Connection

  • male thread: NPT1/2"

Tip Shape

  • straight

Surface Roughness Ra

  • Not defined

Operating Temperature

  • PT100 WW: -200 °C … 600 °C (-328 °F … 1.112 °F)
  • PT100 TF: -50 °C … 200 °C (-58 °F … 392 °F)

Max. Process Pressure (static)

  • Not applicable

Accuracy

  • class A acc. to IEC 60751
  • class B acc. to IEC 60751

Response Time

  • 63% rt = 3 s

Integration Head Transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - Approvals

  • FM XP DIP
  • FM XP NI DIP
  • CSA XP DIP
  • CSA XP NI DIP
  • FM/CSA XP DIP
  • FM/CSA XP NI DIP
  • CSA C/US XP, DIP
  • cCSAus General Purpose

Certification

  • SIL (transmitter only)
show more