Proline T-Mass F 300 Thermal Mass Flowmeter
Brand: Endress+HauserProline T-Mass F 300 Thermal Mass Flowmeter
Brand: Endress+Hauser

The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. Its compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.
- Measuring principle is characterized by a high operable flow range and direct mass flow measurement
- Measurement of utility and process gases as well as gas mixtures in small line sizes
Device properties
- Inline version with DN 15 to 100 (1/2 to 4")
- Bidirectional measurement; high measuring performance
- Patented drift-free sensor with SIL 2
- Compact dual-compartment housing with up to 3 I/Os
- Backlit display with touch control and WLAN access
- Remote display available
- Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
- High level of process control – premium measurement accuracy and repeatability
- Reliable monitoring – detection of process disturbances and reverse flow
- Easy maintenance – removable sensor
- Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
- Reduced complexity and variety – freely configurable I/O functionality
- Integrated verification – Heartbeat Technology
Specifications
Brand
Measuring Principle
- Thermal
Product Headline
- Inline flowmeter with long-term stability and a compact, easily accessible transmitter
- Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
- Measurement of utility and process gases as well as gas mixtures in small line sizes
Sensor Features
- High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Easy maintenance – removable sensor
- Inline version with DN 15 to 100 (1/2 to 4"). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2
Transmitter Features
- Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology
- Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available
Nominal Diameter Range
- DN 15 to DN 100 (1/2" to 4")
Wetted Materials
- Measuring tubes: DN 15 to 50 (1/2 to 2"): stainless cast steel, CF3M/1.4408
- Sensing element - unidirectional: Stainless steel, 1.4404 (316/316L)
- Sensing element - unidirectional: Alloy C22, 2.4602 (UNS N06022)
- Sensing element - Bidirectional: Stainless steel, 1.4404 (316/316L)
- Reverse flow detection: Stainless steel, 1.4404 (316/316L)
- Measuring tubes: DN 65 to 100 (2-1/2 to 4"): stainless steel, 1.4404 (316/316L)
- Process connections - flange Connection: Stainless steel, 1.4404 (F316/F316L)
- Process connections - thread Connection: Stainless steel, 1.4404 (316/316L)
Measured Variables
- Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density
Max. Measurement Error
- Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
Measuring Range
- 0.5 to 3750 kg/h (1.1 to 8250 lb/h)
Max. Process Pressure
- PN40 / Cl. 300 / 20K
Medium Temperature Range
- -40 °C to +180°C (-40 °F to +356 °F)
Ambient Temperature
- -40 to 60°C (-40 to 140°F)
- Transmitter: -50 to 60°C (-50 to 140°F) Optional
- Sensor: -60 to 60°C (-60 to 140°F) Optional
Transmitter Housing Material
- Aluminium, AlSi10Mg, coated
- Polycarbonate
Degree of Protection
- IP66/67, Type 4X enclosure
Display/Operation
- 4-line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
- Remote display available
Outputs
- 3 outputs:
- 4-20 mA HART (active/passive)
- 4-20 mA (active/passive)
- Pulse/frequency/switch output (active/passive)
- Relay output
Inputs
- Status input
- 4-20 mA input
Digital Communication
- HART, Modbus RS485
Power Supply
- DC 24V
- AC 100 to 240V
Hazardous Area Approvals
- ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC
Product Safety
- CE, C-tick
Functional Safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals and Certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Pressure Approvals and Certificates
- PED, CRN
Material Certificates
- 3.1 material
- NACE MR0175/MR0103