iTHERM CompactLine TM311 Compact Thermometer
Brand: Endress+HauseriTHERM CompactLine TM311 Compact Thermometer
Brand: Endress+Hauser
iTHERM CompactLine TM311 sanitary thermometer provides accurate and fast process temperature measurements in hygienic and aseptic applications. Its temperature sensor offers a 4-wire connection or feeds into a smart temperature transmitter with 4 to 20 mA, IO-Link (auto-detect) or switch output. Featuring TipSens technology, the RTD (Pt100; Class A) delivers response times as low as 1.5 s (t90) for optimum process control. This versatile device is a great choice to drive plant standardization.
- Developed for universal use in sterile applications
- High standardization potential for skid builders, machine and plant manufacturers
- Measuring range: -50 to 200 °C (-58 to 392 °F)
- Pressure range: Up to 50 bar (725 psi)
- Protection class: IP69
- Output: Pt100 (4-wire connection); IO-Link, 4 to 20 mA, 1x PNP switch
- International approvals: 3-A, EHEDG, ASME BPE, FDA, EC 1935/2004, EN 2023/2006, TSE/ADI, GB4806-2016, GB9685-2016; Marine approval acc. to DNV GL
- Fast installation and easy commissioning:
- Compact dimensions for installation in tight spaces
- Standard M12 connector with IP69 for easy electrical connection
- Recommended process immersion lengths for optimum measurement
- Preset temperature range
- Excellent temperature measurement performance:
- Short response times as low as 1.5 s (t90)
- High sensor accuracy even with short immersion lengths
- Improved measuring accuracy with transmitter-sensor matching
- Safe and reliable operation:
- Device safety to EN 610101-1 and CSA C/US
- Electromagnetic compatibility (NAMUR NE 21)
- Device diagnostic information (NAMUR NE 43)
- Hygienic design manufactured from high-grade stainless steel
- Marine approval
Specifications
Brand
Measuring Principle
- Resistance Temperature Detector
Characteristic / Application
- metric and imperial style
- compact temperature probe
- fast response time
- high accuracy
- standard and hygienic design
- hygienic process connection
- threaded process connection
Thermowell / Protection Tube
- without
- incl. thermowell
- incl. Tee-/elbow thermowell
Insert / Probe
- pipe version, isolated wires, not flexible
Outer Diameter Protection Tube / Insert
- 3.0 mm (0.12'')
- 6.0 mm (0.24'')
Max. Immersion Length on Request
- up to 600.00 mm (23.62'')
Material Protection Tube/ Thermowell
- 1.4435 Delta-Ferrit < 1%
- 316L
Process Connection
- compression fitting
- Thread
- weld in adapter
- clamp connections acc. to ISO2852
- screwed pipe joint acc. to DIN 11851
- aseptic screwed pipe joint acc. to DIN 11864-1
- metallic sealing system
- thread acc. to ISO 228 for liquiphant adaptor
- Varivent
- SMS 1147
- Tee-/elbow thermowell
Tip Shape
- straight
- reduced
Surface Roughness Ra
- 0.76 μm (29.92 μin)
- 0.38 μm (14.96 μin)
- 0.38 μm (14.96 μin) electropolished
Operating Temperature
- PT 100: -50 °C ...200 °C (-58 °F ...392 °F)
Max. Process Pressure (static)
- at 20 °C: 50 bar (725 psi)
Accuracy
- class A acc. to IEC 60751
Response Time
- t50 = 1 s
- t90 = 1.5 s
Integration Head Transmitter
- no (4…20mA Signal, IO-Link)
Ex - Approvals
- CSA C/US
Certification
- 3A, EHEDG, ASME BPE, FDA, TSE 1935/2004, 2023/2006, 10/2011
- DNV, BV
- RCM