OXY5500 Oxygen Analyzer

Brand: Endress+Hauser

OXY5500 Oxygen Analyzer

Brand: Endress+Hauser
Xpert Xpert

The OXY5500 oxygen analyzer is a compact, stand-alone, single channel analyzer that uses quenched fluorescence (QF) technology to reliably measure oxygen in natural gas and gas processing applications. A sensor probe is inserted into the process stream and is connected to the controller by an optical fiber. Featuring an LCD display and built-in data logger, the OXY5500 also has full sample conditioning systems available as well as software for a PC interface.

  • Natural gas quality measurements in production, storage, transportation, and distribution
  • Monitoring in natural gas, upstream of production and gathering sites
  • Measurable range from ppm levels to 0-20% O2
  • Trace measurements as low as 0-10 ppmv oxygen in hydrogen for electrolyzer applications
  • Ideal for CCUS applications since optical oxygen measurement is unaffected by CO2or H2S in the process
Features
  • Easy to navigate display and menu
  • Small optical sensor with no membrane or consumable chemicals
  • Optical measurement with fast, continuous response
  • Excellent long-term stability
  • Not affected by H2S
  • No moving parts, simple operation
  • Data logging for 30 days

Specifications

Measuring Principle

  • Quenched Fluorescence

Channels

  • 1

Analyte and Measurement Ranges

  • O2 (Oxygen):
  • 0 to 100 ppmv (minimum)
  • 0 to 20% volume (maximum)

Measured Variables

  • Concentration
  • Cell Pressure
  • Cell Temperature

Ambient Temperature

  • -20 to 50°C (-4 to 122°F)

Operating Pressure Range

  • Inlet Pressure: 140 to 275 kPa (20 to 40 psig)
  • Sample Cell: 800 to 1200 mbara

Analyzer Wetted Materials

  • 304 & 316 stainless steel
  • FKM O-Rings

Power Supply

  • 108 to 253 VAC, 50/60 Hz; 5.3 Watts at 120VAC; 6.6 Watts at 240VAC
  • 9 to 30 VDC (CSA), 18 to 30 VDC (IECEx/ATEX); 4.7 Watts at 24VDC

Communication

  • Analog Output: Two 4-20 mA outputs
  • Analog Input: One 4-20 mA input (sample pressure)
  • Fieldbus: RS-232C, RS-485, & Ethernet 10/100 with Modbus
  • Output Relays: Qty 2, 250 mA max load (Concentration and Fault Alarms)
  • USB 2.0 Works With Service Software Only
  • 4 GB Internal Memory with Internal Data Logging

Housing Materials

  • Electronics: 304 or 316L stainless steel

Hazardous Area Approvals

  • ATEX / IECEx - Zone 2
  • CSA Class I, Division 2

Degree of Protection

  • IP64, Type 4X

Product Safety

  • CE
  • RCM
  • FCC
show more