Raman Rxn-40 Probe

Brand: Endress+Hauser

Raman Rxn-40 Probe

Brand: Endress+Hauser
Extended Extended

The Raman Rxn-40 probe is a sealed immersion probe for in situ Raman spectroscopy of liquid-phase samples in a laboratory or process plant setting. The process connection for the Raman Rxn-40 can be swaged, compression-mounted, flange-mounted, or installed in an Endress+Hauser flow cell, and is NeSSI compatible. These versatile options allow for direct insertion in slip-streams, drain-values, reactors, circulation loops, blend headers, and inlet or outlet pipework.

  • Chemical: reaction monitoring, blending, catalysis, feed and final product monitoring
  • Polymer: polymerization reaction monitoring, extrusion monitoring, polymer blending
  • Oil & Gas: fuel blending, fuel characterization
  • Pharmaceutical: API reaction monitoring, crystallization, polymorph, blending
Features
  • Customizable to your process
  • Robust design with a range of process connections
  • In situ/no transfer lines or fast-loops required
  • Faster, simpler installation
  • Support for a range of chemical processes and corrosivity requirements
  • Ensures safety and meets regulatory requirements
  • Suitable for hazardous/classified environments

Specifications

Measuring Principle

  • Raman spectroscopy

Laser Wavelength

  • 532 nm, 785 nm, 1000 nm

Spectral Coverage

  • Probe spectral coverage is limited by the coverage of the analyzer being used

Ambient Temperature

  • Nonexplosive environments: -30 to 150 °C (-22 to 302 °F)
  • Explosive environments: T4: –20 to 70 °C (–4 to 158 °F)
  • Explosive environments: T6: –20 to 65 °C (–4 to 149 °F)
  • Limited to normal ambient temperature
  • IEC 60079-0 for Korea

Maximum Laser Power Into Probehead (mW)

  • < 499

Sample Interface

  • Temperature, Rxn-40 mini configuration: -30 to 120 °C (-22 to 248 °F) (316L stainless steel)
  • Temperature, Rxn-40 mini configuration: -30 to 150 °C (-22 to 302 °F) (C276 alloy)
  • Temperature, Rxn-40 mini configuration: -30 to 150 °C (-22 to 302 °F) (Grade 2 Titanium)
  • Temperature ramp: ≤ 30 °C/min; ≤ 54 °F/min
  • Temperature, Rxn-40: -30 to 120 °C (-22 to 248 °F) (316L stainless steel)
  • Temperature, Rxn-40: -30 to 280 °C (-22 to 536 °F) (C276 alloy)
  • Temperature, Rxn-40: -30 to 315 °C (-22 to 599 °F) (Grade 2 Titanium)
  • Flange: ASME B16.5 and DIN EN1092 Type B flanges available upon request
  • Relative humidity: up to 95%, non-condensing

Pressure

  • Min pressure: Full vacuum (0 bara) but not ultrahigh vacuum (UHV) where outgassing maybe a concern
  • Max pressure, 3/4 and 1 inch Rxn-40: 182.8 barg (2651 psig) (C276 alloy)
  • Max pressure, 3/4 and 1 inch Rxn-40: 72.2 barg (1047 psig) (Grade 2 titanium)
  • Max pressure, Rxn-40 mini configuration: 157.1 barg (2279 psig) (316L stainless steel)
  • Max pressure, Rxn-40 mini configuration: 199.3 barg (2890 psig) (C276 alloy)
  • Max pressure, Rxn-40 mini configuration: 153.6 barg (2228 psig) (Grade 2 titanium)
  • Max pressure, 1/2 inch Rxn-40: 142.4 barg (2066 psig) (316L stainless steel)
  • Max pressure, 1/2 inch Rxn-40: 158.1 barg (2293 psig) (C276 alloy)
  • Max pressure, 1/2 inch Rxn-40: 65.2 barg (946 psig) (Grade 2 titanium)
  • Max pressure, 3/4 and 1 inch Rxn-40: 169.5 barg (2458 psig) (316L stainless steel)

Wetted Materials

  • Metal: C276 alloy, 316L stainless steel, or Grade 2 titanium
  • Window: High-purity sapphire

Fiber Optic Cable

  • Cable sold separately

Length

  • Rxn-40 mini configuration immersible length: 36 mm (1.42 inch)
  • Rxn-40: Maximum immersible length is dependent on material choice

Diameter

  • 12.7, 19.05, 25.4 mm
  • 0.5, 0.75, 1 inch

Hazardous Area Certifications

  • ATEX, CSA, IECEx
show more