iTHERM ModuLine TR65 Industrial Modular Thermometer
Brand: Endress+HauseriTHERM ModuLine TR65 Industrial Modular Thermometer
Brand: Endress+Hauser
The robust thermometer designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. The sensor may be used in direct contact without thermowell or where the application requires it, spring load inside of a separate thermowell. Flexible configuration possible.
- Fine Chemicals
- Petrochemical industry
- Power stations
- Environmental engineering
- Measuring range: -200 to +600 °C (-328 to 1112 °F)
- Static pressure range up to 75 bar dependent on the used process connection
- Protection class: IP68
- Types of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), flameproof (Ex d), non-sparking (Ex nA)
- High degree of insert compatibility and design as per DIN 43772
- High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths
Specifications
Brand
Measuring Principle
- Resistance Temperature Detector
Characteristic / Application
- metric style
- modular temperature assembly
- for heavy duty applications
- suitable for hazardous areas
- threaded process connection
- without neck
Thermowell / Protection Tube
- without (not intended to use with thermowell)
Insert / Probe
- mineral insulated (MI), flexible
Outer Diameter Protection Tube / Insert
- 3.0 mm (0.12'')
- 6.0 mm (0.24'')
Max. Immersion Length on Request
- up to 30,000.00 mm (1,181.10'')
Material Protection Tube/ Thermowell
- 1.4404 (316L)
Process Connection
- male thread: NPT1/2", NPT3/4", M20x1,5
- compression fitting: NPT1/2", NPT3/4"
Tip Shape
- straight
Surface Roughness Ra
- Not defined
Operating Temperature
- PT100 TF iTHERM StrongSens: -50 °C ...500 °C (-58 °F ...932 °F)
- PT100 WW: -200 °C ...600 °C (-328 °F ...1,112 °F)
- PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F)
Max. Process Pressure (static)
- at 20 °C: 80 bar (1,160 psi)
Accuracy
- class A acc. to IEC 60751
- class AA acc. to IEC 60751
Response Time
- t50 = 2 s
- t90 = 5 s
Integration Head Transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - Approvals
- ATEX Ex ia, Ex d, Ex nA
- IECEx Ex ia, Ex d, Ex tD
- EAC Ex ia, Ex d
- NEPSI Ex ia, Ex d
- Explosion proof
Certification
- Gost Metrology
- SIL (transmitter only)