Radar Measurement Micropilot NMR84

Brand: Endress+Hauser

Radar Measurement Micropilot NMR84

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Xpert Xpert

Micropilot NMR84 is used for custody transfer and inventory control applications with NMi- and PTB-approvals. It meets the relevant requirements according to OIML R85 and API 3.1B. The NMR84 free space radar with drip-off planar antenna is specifically suited for stilling well applications. The superior drip-off antenna design with proven track record eliminates problems caused by condensation.

With planar antenna particularly suited for stilling well applications.

  • Process connections: Flanges
  • Temperature: -40 to +150°C (-40 to +302°F)
  • Pressure: Vacuum to +25bar (Vacuum to +362psi)
  • Maximum measuring range: 40m (131ft)
  • Accuracy: ±0.5mm (±0.02")
  • Transmitting frequency: 6GHz
  • International explosion protection and custody transfer certificates, overfill prevention WHG, SIL
Features
  • Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy) for high level of safety
  • Maximum reliability through accuracy up to ±0.5mm (±0.02")
  • Developed according to international metrology recommendations such as OIML R85 and API MPMS
  • Local and country-specific certifications like NMi or PTB for custody transfer applications
  • Simplified installation and trouble-free operations due to easy connection to major DCS systems via open protocols
  • Unique drip-off antenna design eliminates measurement error due to condensation build-up

Specifications

Product Family

  • Micropilot

Measuring Principle

  • Level Radar

Characteristic / Application

  • Planar antenna, 6GHz: High precision measurement for for storage tanks up to 30m (98ft)

Specialities

  • Custody transfer level measurement

Supply / Communication

  • 85-264 VAC
  • 52-74 VAC
  • 19-64 VDC

Accuracy

  • up to 0.5 mm

Ambient Temperature

  • Standard: -40°C…60°C (-40°F...140°F)
  • For calibration to regulatory standards: -25°C…55°C (-13°F...131°F)

Process Temperature

  • -40°C…150°C (-40°F...302°F)

Process Pressure / Max. Overpressure Limit

  • Vacuum ... 25 bar abs

Main Wetted Parts

  • 316L, PTFE

Process Connection

  • Flange: DN100/4"…DN300/12"
  • UNI-flange: DN150/6"…DN300/12"

Max. Measurement Distance

  • 40 m (131 ft)
  • For calibration to regulatory standards: 30 m (98 ft)

Communication

  • Output - Fieldbus: Modbus RS485, V1, WM550
  • Output: HART, BPM and TRL/2 (via GE option)
  • Analog 4-20mA output (Exi/ Exd)
  • Relay output (Exd)
  • Analog 4-20mA input (Exi/ Exd)
  • 2-, 3-, 4-wire RTD input
  • Discrete input (Exd, passive/ active)

Certificates / Approvals

  • ATEX, FM, IEC Ex, EAC, JPN Ex, KC Ex
  • INMETRO, NEPSI, UK Ex

Safety Approvals

  • Overfill protection WHG
  • SIL

Design Approvals

  • EN 10204-3.1
  • NACE MR0175, MR0103
  • AD2000

Metrological Approvals and Certificates

  • OIML, NMi, PTB

Options

  • Redundant fieldbus
  • Alu-coated or 316L housing
  • Weather protection cover

Application Limits

  • Maximum measuring range is dependent on the tank form and/ or application
  • Strong condensate or build-up formation