Guided Radar Measurement Time-Of-Flight Levelflex FMP52
Brand: Endress+HauserGuided Radar Measurement Time-Of-Flight Levelflex FMP52
Brand: Endress+Hauser

Levelflex FMP52 for level measurement in aggressive liquids with chemically resistant gap-free PFA-coated probe. All wetted parts are FDA listed materials. FMP52 guided radar offers maximum reliability even in case of moved surface. Levelflex FMP52 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Version with rod or rope probe.
- Process connections: Flange or process connections for hygiene requirements (Tri-Clamp, 11851)
- Temperature: -50 to +200°C (-58 to +392°F)
- Pressure: -1 to +40bar (-14.5 to +580psi)
- Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)
- Accuracy: Rod probe ±2mm (0.08")
- International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval, 5-point linearity protocol
- Reliable measurement even for changing product and process conditions
- HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
- Highest reliability due to new Multi-Echo Tracking evaluation
- Hardware and software developed according to IEC 61508 up to SIL3
- Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
- Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
- World's easiest proof test for SIL and WHG saves time and costs
Specifications
Brand
Measuring Principle
- Guided radar
Characteristic / Application
- Premium device coated for corrosive media
- Rod probe, Rope probe
- Wetted parts FDA listed materials, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias
Interface Measurement
- Clean interfaces liquid/ liquid
- Simultaneous measurement of interface and overall level
Specialities
- Heartbeat Technology
- Bluetooth® commissioning
- Operation and maintenance SmartBlue App
- HistoROM
- RFID TAG for easy identification
Supply / Communication
- 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
- 4-wire (HART)
- Bluetooth® wireless technology and App (optional)
Accuracy
- Rope probe ≤ 15 m (49 ft): +/- 2 mm (0.08 in)
- Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
- Rod probe: +/- 2 mm (0.08 in)
Ambient Temperature
- -40...+80 °C
- -40...+176 °F
Process Temperature
- -50...+200 °C
- -58...+392 °F
Process Pressure / Max. Overpressure Limit
- Vacuum...40 bar
- Vacuum...580 psi
Main Wetted Parts
- Rod probe: 304, 304L, 316L, PTFE, PFA
- Rope probe: 304, 304L, 316, 316L, PTFE, PFA
Process Connection
- ASME 1 1/2"...6"
- DN50...DN100
- JIS 10K
Process Connection Hygienic
- Tri-Clamp
- DIN11851
Sensor Length
- Rod probe: 4 m (13 ft)
- Rope probe: 45 m (148 ft)
Max. Measurement Distance
- Rod: 4 m (13 ft) Min DK>1.6
- Rope: 25 m...30 m (82 ft...98 ft) Min DK>1.6; 30 m...45 m (98 ft...148 ft) Min DK>1,9
Communication
- 4...20 mA HART
- PROFIBUS PA
- FOUNDATION Fieldbus
- Bluetooth® wireless technology
Certificates / Approvals
- ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex
Safety Approvals
- Overfill protection WHG
- SIL
Design Approvals
- EN 10204-3.1
- ASME B31.1, B31.3
- AD2000
Hygienic Approvals
- 3A, EHEDG
Marine Approval
- GL/ ABS/ LR/ BV/ DNV
Options
- Sensor remote with 3 m/ 9 ft cable
- Gas-tight feed through
- Remote operation via SmartBlue App using Bluetooth®