Proline Prowirl O 200 Vortex Flowmeter

Brand: Endress+Hauser

Proline Prowirl O 200 Vortex Flowmeter

Brand: Endress+Hauser
Extended Extended
Heartbeat Technology Heartbeat Technology

Prowirl O is ideally suited for reliable process control in demanding gas and steam applications with high process pressure. Moreover, its design ensures maximum safety in main and ancillary processes. With genuine loop-powered technology, Prowirl O 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.

  • Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
  • The specialist for applications with high process pressure

Device properties

  • Saturated steam mass flow up to PN 250 (Class 1500)
  • Full compliance with NACE (MR0175/MR0103)
  • Flexible positioning of pressure cell
  • Display module with data transfer function
  • Robust dual-compartment housing
  • Plant safety: worldwide approvals (SIL, Haz. area)
Features
  • Better process control – integrated temperature and pressure measurement for steam and gases
  • Increased mechanical integrity for flow measurement – special sensor design
  • Same accuracy down to Re 10 000 – most linear Vortex meter body
  • Long-term stability – robust drift-free capacitive sensor
  • Convenient device wiring – separate connection compartment, various Ethernet options
  • Safe operation – no need to open the device
  • Integrated verification – Heartbeat Technology

Specifications

Measuring Principle

  • Vortex

Product Headline

  • Flowmeter optimized for requirements of high-pressure mating pipes
  • Better process control – integrated temperature and pressure measurement for steam and gases
  • The specialist for applications with high process pressure

Sensor Features

  • Increased mechanical integrity for flow measurement – special sensor design. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor
  • Saturated steam mass flow up to PN 250 (Class 1500). Full compliance with NACE (MR0175/MR0103). Flexible positioning of pressure cell

Transmitter Features

  • Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology
  • Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area)

Nominal Diameter Range

  • DN 15 to 300 (1/2 to 12")

Wetted Materials

  • Measuring tube: 1.4408 (CF3M)
  • DSC sensor: UNS N07718 similar to Alloy 718, 2.4668
  • Process connection: 1.4404/F316/F316L

Measured Variables

  • Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. Measurement Error

  • Volume flow (liquid): ±0.75 %
  • Volume flow (steam, gas): ±1.00 %
  • Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
  • Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
  • Mass flow (liquid): ±0.85%

Measuring Range

  • Liquid: 0.2 to 1,895 m³/h (0.15 to 1,115 ft³/min), depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
  • Steam, gas: 1.5 to 25,285 m³/h (0.9 to 14,880 ft³/min), depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

Max. Process Pressure

  • PN 250, Class 1500, 40K

Medium Temperature Range

  • Standard: –40 to +260 °C (–40 to +500 °F)
  • High/low temperature (option): –200 to +400 °C (–328 to +752 °F)

Ambient Temperature

  • Compact version (standard): –40 to +80 °C (–40 to +176 °F)
  • Compact version (option): –50 to +80 °C (–58 to +176 °F)
  • Remote version (standard): –40 to +85 °C (–40 to +185 °F)
  • Remote version (option): –50 to +85 °C (–58 to +185 °F)

Sensor Housing Material

  • Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter Housing Material

  • AlSi10Mg, coated; 1.4404 (316L)

Degree of Protection

  • Compact version: IP66/67, type 4X enclosure
  • Sensor remote version: IP66/67, type 4X enclosure
  • Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation

  • 4‐line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 4‐20 mA HART (passive)
  • 4‐20 mA (passive)
  • Pulse/frequency/switch output (passive)

Inputs

  • 4‐20 mA (passive)

Digital Communication

  • HART, PROFIBUS PA, FOUNDATION Fieldbus

Power Supply

  • DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
  • DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
  • DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
  • DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus, JPN

Product Safety

  • CE, C-TICK, EAC, UK Ex

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Marine Approvals and Certificates

  • ABS, LR, BV, DNV

Pressure Approvals and Certificates

  • PED, CRN

Material Certificates

  • 3.1 material
  • NACE MR0175/MR0103, PMI (on request); only Class 900/1500: welding test acc. to ISO 15614‐1, similar to ASME IX (on request)
show more