Proline Prowirl O 200 Vortex Flowmeter

Brand: Endress+Hauser

Proline Prowirl O 200 Vortex Flowmeter

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Extended Extended
Heartbeat Technology Heartbeat Technology

Prowirl O is ideally suited for reliable process control in demanding gas and steam applications with high process pressure. Moreover, its design ensures maximum safety in main and ancillary processes. with genuine loop-powered technology, Prowirl O 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.

  • Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
  • The specialist for applications with high process pressure

Device properties

  • Saturated steam mass flow up to PN 250 (Class 1500)
  • Full compliance with NACE (MR0175/MR0103)
  • Flexible positioning of pressure cell
  • Display module with data transfer function
  • Robust dual-compartment housing
  • Plant safety: worldwide approvals (SIL, Haz. area)
Features
  • Better process control – integrated temperature and pressure measurement for steam and gases
  • Increased mechanical integrity for flow measurement – special sensor design
  • Same accuracy down to Re 10 000 – most linear Vortex meter body
  • Long-term stability – robust drift-free capacitive sensor
  • Convenient device wiring – separate connection compartment, various Ethernet options
  • Safe operation – no need to open the device
  • Integrated verification – Heartbeat Technology

Specifications

Product Family

  • Prowirl

Measuring Principle

  • Vortex

Product Headline

  • Flowmeter optimized for requirements of high-pressure mating pipes
  • Better process control – integrated temperature and pressure measurement for steam and gases
  • The specialist for applications with high process pressure

Sensor Features

  • Increased mechanical integrity for flow measurement – special sensor design. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor
  • Saturated steam mass flow up to PN 250 (Class 1500). Full compliance with NACE (MR0175/MR0103). Flexible positioning of pressure cell

Transmitter Features

  • Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology
  • Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area)

Nominal Diameter Range

  • DN 15 to 300 (1/2 to 12")

Wetted Materials

  • Measuring tube: 1.4408 (CF3M)
  • DSC sensor: UNS N07718 similar to Alloy 718, 2.4668
  • Process connection: 1.4404/F316/F316L

Measured Variables

  • Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature

Max. Measurement Error

  • Volume flow (liquid): ±0.75 %
  • Volume flow (steam, gas): ±1.00 %
  • Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
  • Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
  • Mass flow (liquid): ±0.85%

Measuring Range

  • Liquid: 0.2 to 1,895 m³/h (0.15 to 1,115 ft³/min), depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
  • Steam, gas: 1.5 to 25,285 m³/h (0.9 to 14,880 ft³/min), depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)

Max. Process Pressure

  • PN 250, Class 1500, 40K

Medium Temperature Range

  • Standard: –40 to +260 °C (–40 to +500 °F)
  • High/low temperature (option): –200 to +400 °C (–328 to +752 °F)

Ambient Temperature

  • Compact version (standard): –40 to +80 °C (–40 to +176 °F)
  • Compact version (option): –50 to +80 °C (–58 to +176 °F)
  • Remote version (standard): –40 to +85 °C (–40 to +185 °F)
  • Remote version (option): –50 to +85 °C (–58 to +185 °F)

Sensor Housing Material

  • Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)

Transmitter Housing Material

  • AlSi10Mg, coated; 1.4404 (316L)

Degree of Protection

  • Compact version: IP66/67, type 4X enclosure
  • Sensor remote version: IP66/67, type 4X enclosure
  • Transmitter remote version: IP66/67, type 4X enclosure

Display/Operation

  • 4‐line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 4‐20 mA HART (passive)
  • 4‐20 mA (passive)
  • Pulse/frequency/switch output (passive)

Inputs

  • 4‐20 mA (passive)

Digital Communication

  • HART, PROFIBUS PA, FOUNDATION Fieldbus

Power Supply

  • DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
  • DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
  • DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
  • DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus, JPN

Product Safety

  • CE, C-TICK, EAC, UK Ex

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Marine Approvals and Certificates

  • ABS, LR, BV, DNV

Pressure Approvals and Certificates

  • PED, CRN

Material Certificates

  • 3.1 material
  • NACE MR0175/MR0103, PMI (on request); only Class 900/1500: welding test acc. to ISO 15614‐1, similar to ASME IX (on request)
show more