Flow-X Flow Computer

Brand: Endress+Hauser

Flow-X Flow Computer

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Alabama, Mississippi, Louisiana, Florida, New York, Connecticut, Massachusetts, Vermont, New Hampshire, Maine, Rhode Island, Puerto Rico, US Virgin Islands and parts of Tennessee and Arkansas.

Xpert Xpert

The Flow-X flow computer provides gas volume conversion, event logging, parameter logging, and reports using state-of-the-art technology. Identical modules are combined in different housings, offering a multi-stream version Flow-X/P for 1 - 4 measuring distances with a local touch screen, or the version Flow-X/S for smaller installations with one measuring distance. It is the ideal partner for custody transfer gas metering solutions in installations with FLOWSIC600 ultrasonic gas flowmeters.

  • Custody gas metering
  • Demanding natural gas and process gas applications

Device properties:

  • MID approved configuration for gas metering streams with FLOWSIC600
  • Powerful modules for demanding applications
  • Each module features CPU, memory and equal in/outputs
  • Intuitive user interface for graphics display and web browser
  • True remote access via Ethernet
  • Station computer for multiple streams
Features
  • Reduced planning and installation costs through standard configurations
  • Very accurate volume conversion with multiple calculation cycles per second
  • High reliability through independent modules with their own volume conversion and storage of measured values, counter readings and events
  • Easy extension of installations with modules featuring equal in/outputs and 100% software configuration
  • Reduced service and maintenance costs with tamper-proof remote maintenance
  • Cost-efficient and flexible system integration of multiple streams

Specifications

Measuring Principle

  • Flow Computer

Measuring Variables

  • gas volume conversion, event logging, parameter logging, and reports

Number of Applications

  • Support up to 4 gas runs or 2 liquid runs per module (Flow-X/M, Flow-X/C)

Calculations

  • Gas property calculations: AGA 5, AGA 8 Part 1, AGA 8 Part 2 (GERG-2008), AGA 10 AGA NX-19; GERG-2008; GERG91mod (GOST 30319.2-1996); GOST 30319.2-2015; GSSSD MR-113; ISO 6976, ISO 12213 Parts 2 and 3; S-GERG
  • Flow rate calculations: AGA 3, AGA 7, AGA 9, AGA 11

Electrical Connection

  • Current consumption: Flow-X/P0, X/M, X/S: ≤ 0.4 A nominal; ≤ 0.8 A maximal; Flow-X/C: ≤ 0.6 A nominal; ≤ 1.0 A maximal
  • Voltage 24 VDC (± 10%), with redundant connections

Ambient Temperature

  • Flow-X/S: -40 °C ... +75 °C
  • Flow-X/C, Flow-X/P, Flow-X/R: 0 °C ... +60 °C

System

  • CPU and memory: 800 MHz, 512 MB RAM, 1 GB flash memory
  • Clock: Real-time clock, accuracy better than 1 sec/day
  • Gold cap for date and time retention
  • Watchdog: Hardware and software watchdog timer
  • Tamper switch: Mechanical tamper switch to prevent changing of the application and vital parameters within that application

Supported Gas Chromatographs

  • Supports all common gas chromatographs (including ABB NGC8200 series, ABB BTU8100, Danalyser, Yamatake HGC, Encal 3000, Angus GQA, Siemens Maxum and Sitrans)

Conformities

  • 2014/32/EU Measuring Instruments Directive (MID)
  • Directive 2014/30 / EC relating to electromagnetic compatibility
  • 2012/19/EU WEEE Directive (WEEE 2)
  • 2011/65/EU RoHS
  • OIML R117-1
  • WELMEC 7.2, 8.3, 8.8
  • API 21.1

Hazardous Area Approvals

  • Applies for FlowX/M and X/S only
  • Class I, Division 2, Groups A, B, C, and D, T4
  • Class I, Zone 2, Group IIC, T4
  • IECEx Ex ec IIC Gc
  • ATEX II 3 G Ex ec IIC Gc

Inputs

  • 6x analog transmitter input, high accuracy
  • Input types are 4 to 20 mA, 0 to 20 mA, 0 to 5 V, 1 to 5 V
  • Accuracy mA inputs; 0.002% FS at 21 °C, 0.008% at full ambient range of 0-60 °C, long-term stability 0.01% per year
  • Resolution: 24 bits. Analog inputs have the same earthing relative to all other electronic devices
  • 16x digital status inputs. Resolution 100ns (10MHz)

Outputs

  • 4x analog output for process outputs and flow / pressure control. Resolution 14 bits, 0.075% FS
  • Analog outputs share same ground floating in relation to all other electronics
  • 16x digital output, open collector. Rating 100mA @24V
show more