iTHERM FlameLine TAF12D High Temperature Thermometer
Brand: Endress+HauseriTHERM FlameLine TAF12D High Temperature Thermometer
Brand: Endress+Hauser
Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell and the internal sheath made from ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.
- The TAF12D are assemblies with double ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.
- Process temperatures: up to +1700 °C (+3092 °F)
- Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance
- Long term stable measurement due to sensor protection with non-porous materials
- Flexible product selection by modular design
- Optimized life cycle costs by means of replaceable spare parts
Specifications
Brand
Measuring Principle
- Thermocouple
Characteristic / Application
- metric style
- modular temperature assembly
- high temperature probe (furnace)
- incl. double ceramic thermowell
Thermowell / Protection Tube
- ceramic protection tube and inner tube
Insert / Probe
- ceramic capilarry, rigid
Outer Diameter Protection Tube / Insert
- 14.0 mm (0.55")
- 15.0 mm (0.59")
Max. Immersion Length on Request
- up to 3,500.00 mm (137.80'')
Material Protection Tube/ Thermowell
- Ceramic (C610/C799)
Process Connection
- compression fitting: G3/4", G1", G1-1/2"
- adjustable Flange
Tip Shape
- straight
Operating Temperature
- Type S: 0 °C ...1,600 °C (32 °F ...2,912 °F)
- Type R: 0 °C ...1,600 °C (32 °F ...2,912 °F)
- Type B: 600 °C ...1,700 °C (1,112 °F ...3,092 °F)
Max. Process Pressure (static)
- at 20 °C: 1 bar (15 psi)
Accuracy
- class 2 acc. to IEC 60584
Integration Head Transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Certification
- SIL (transmitter only)