The robust Promass E has a long-standing reputation as a reliable solution accurately measuring liquids and gases in a wide range of standard applications in various industries. With its compact transmitter Promass E 300 offers high flexibility in terms of operation and system integration: access from one side, remote display, improved connectivity options. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

  • Measuring principle operates independently of physical fluid properties such as viscosity or density
  • Accurate measurement of liquids and gases for a wide range of standard applications

Device properties

  • Compact dual-tube sensor
  • Medium temperature up to +150 °C (+302 °F)
  • Process pressure up to 100 bar (1450 psi)
  • Compact dual-compartment housing with up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
Features
  • Cost-effective – multipurpose device; an alternative to conventional volumetric flowmeters
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in-/outlet run needs
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology

Specifications

Measuring Principle

  • Coriolis

Product Headline

  • Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter
  • Accurate measurement of liquids and gases for a wide range of standard applications

Sensor Features

  • Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space‐saving installation – no in-/outlet run needs
  • Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F)

Transmitter Features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology
  • Process pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access

Nominal Diameter Range

  • DN 8 to 80 (3/8 to 3")

Wetted Materials

  • Measuring tube: 1.4539 (904L)
  • Connection: 1.4404 (316/316L)

Measured Variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. Measurement Error

  • Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)
  • Volume flow (liquid): ±0.15 %
  • Mass flow (gas): ±0.50 %
  • Density (liquid): ±0.0005 g/cm³

Measuring Range

  • 0 to 180,000 kg/h (0 to 6615 lb/min)

Max. Process Pressure

  • PN 100, Class 600, 63K

Medium Temperature Range

  • –40 to +150 °C (–40 to +302 °F)

Ambient Temperature

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor Housing Material

  • 1.4301 (304), corrosion resistant

Transmitter Housing Material

  • AlSi10Mg, coated; stainless steel for hygenic transmitter design

Degree of Protection

  • Standard: IP66/67, Type 4X enclosure
  • IP69

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA WirelessHART
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Double pulse output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital Communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power Supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product Safety

  • CE, C-tick, EAC marking

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Marine Approvals and Certificates

  • LR approval, DNV approval, ABS approval, BV approval, CCS approval

Pressure Approvals and Certificates

  • PED, CRN

Material Certificates

  • 3.1 material

Hygienic Approvals and Certificates

  • 3-A, EHEDG, cGMP