Capacitance Point Level Detection Liquicap FTI52

Brand: Endress+Hauser

Capacitance Point Level Detection Liquicap FTI52

Brand: Endress+Hauser
Lean Lean

Liquicap FTI52 is a rope probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids.

Due to its active build-up compensation FTI52 offers maximum reliability and is suited for a wide range of applications thanks to international certificates.

The parts in contact with the process are made of corrosion-resistant and FDA-listed materials - this guarantees a high safety standard.

For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.

  • Process connections: Flanges, threads, special hygienic process connections
  • Temperature: -80 to +200 °C (-112 to +392 °F)
  • Pressure: Vacuum to +100 bar (vacuum to +1,450 psi)
  • Sensor length: 12 m (39 ft)
  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval
Features
  • Cost savings thanks to easy and fast commissioning as calibration takes place at the press of a button
  • Reliable and safe measurement due to active build-up compensation
  • Reliable and universal application thanks to wide range of certificates and approvals
  • Short reaction time
  • Material in contact with the process made of corrosion-resistant and FDA-listed materials
  • Two-stage overvoltage protection
  • No need for recalibration after replacing electronics

Specifications

Measuring Principle

  • Capacitive Liquid

Characteristic / Application

  • Capacitive Rope probe

Specialities

  • Interface detection
  • Foam detection

Ambient Temperature

  • -50... +70 °C (-58... +158 °F)
  • With separate housing: -50... +120 °C (-58... +248 °F)

Process Temperature

  • -80... +200 °C (-112... +392 °F)

Process Pressure / Max. Overpressure Limit

  • Vacuum...100 bar (1,450 psi)

Main Wetted Parts

  • Insulation material: FEP, PFA
  • 316L

Process Connection

  • G 3/4 ... 1-1/2
  • NPT 3/4 ... 1-1/2
  • Flange from DN25.../ASME 1".../JIS 10K...

Process Connection Hygienic

  • Tri-Clamp ISO2852 gap free plated
  • Dairy coupling
  • Flush mount

Sensor Length

  • Total length of probe: max 12 m (39 ft)

Communication

  • 2- wire 19-253 VAC
  • 3-wire
  • PFM
  • Relay DPDT
  • DC-PNP
  • 8/16 mA

Certificates / Approvals

  • ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC

Safety approvals

  • Overfill prevention WHG
  • SIL

Design Approvals

  • EN 10204-3.1
  • NACE MR0175

Marine Approval

  • GL/ ABS/ DNV

Options

  • Inactive length
  • Active build-up compensation
  • Separate housing

Components

  • Transmitter
  • PFM: FTC325, FTC625, FTC470Z, FTC471Z
  • 3-wire: FTC325

Application Limits

  • Notice the pressure and temperature derating
  • Notice for non conductive medium the DK
show more