Cubemass DCI Coriolis Flowmeter
Brand: Endress+HauserCubemass DCI Coriolis Flowmeter
Brand: Endress+HauserCubemass DCI is the proven sensor for the measurement of smallest flow rates in skids, test rigs and industrial robotics, e.g. in applications like lacquering or surface finishing. Neither high pressure nor alternating flow conditions compromise its accuracy. Equipment manufacturers value Cubemass CDI as compact Coriolis sensor with various communication possibilities.
- Measuring principle operates independently of physical fluid properties such as viscosity or density
- Measuring accurately smallest quantities of liquids and gases
Device properties
- Nominal diameter: DN 1 to 6 (1/24 to 1/4")
- Process pressure up to 400 bar (5800 psi)
- Medium temperature up to +200 °C (+392 °F)
- Device as compact or remote version
- Flexible outputs
- Modbus RS485
- Measuring accurately smallest quantities of liquids and gases
- Space-saving installation – compact single-tube design
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Suitable for skids – lightweight sensor
- High flexibility in system integration – wide range of communication interfaces
- Fast commissioning – pre-configured devices
- Automatic recovery of data for servicing
Specifications
Brand
Measuring Principle
- Coriolis
Product Headline
- Compact sensor for smallest quantities with seamless system integration
- Measuring accurately smallest quantities of liquids and gases
Sensor Features
- Space-saving installation – compact single-tube design
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Suitable for skids – lightweight sensor
- Nominal diameter: DN 1 to 6 (1/24 to 1/4"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).
Transmitter Features
- High flexibility in system integration – wide range of communication interfaces
- Fast commissioning – pre-configured devices. Automatic recovery of data for servicing
- Device as compact or remote version. Flexible outputs. Modbus RS485
Nominal Diameter Range
- DN 1 to 6 (1/24 to 1/4")
Wetted Materials
- Measuring tube: 1.4539 (904L)
- Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured Variables
- Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. Measurement Error
- Mass flow (liquid): ±0.1 %
- Volume flow (liquid): ±0.1 %
- Mass flow (gas): ±0.5 %
- Density (liquid): ±0.0005 g/cm3
Measuring Range
- 0 to 1000 kg/h (0 to 37 lb/min)
Max. Process Pressure
- PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium Temperature Range
- –50 to +200 °C (–58 to +392 °F)
Ambient Temperature
- Standard: –20 to +60 °C (–4 to +140 °F)
- Option: –40 to +60 °C (–40 to +140 °F)
Sensor Housing Material
- 1.4301 (304), corrosion resistant
Transmitter Housing Material
- Powder‐coated die‐cast aluminium
Degree of Protection
- IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation
- 4‐line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
Outputs
- 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive)
- Pulse/frequency/switch output (passive), phase‐shifted pulse
- Relay
Inputs
- 1 modular input: status
Digital Communication
- HART, Modbus RS485
Power Supply
- DC 16 to 62 V
- AC 85 to 260 V (45 to 65 Hz)
- AC 20 to 55 V (45 to 65 Hz)
Hazardous Area Approvals
- ATEX, IECEx, NEC/CEC, NEPSI
Other Approvals and Certificates
- 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
- CRN
Functional Safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals and Certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Material Certificates
- 3.1 material