TC15 Modular TC Thermometer

Brand: Endress+Hauser

TC15 Modular TC Thermometer

Brand: Endress+Hauser
Extended Extended

The high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.

  • Universal range of application
  • Particularly suitable for steam and gas applications with high process pressures and temperatures
  • Measuring range: –40 to 1100 °C (–40 to 2012 °F)
  • Static pressure range up to 400 bar (5800 psi)
  • Degree of protection: up to IP68
Features
  • High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths
  • High degree of insert compatibility and design as per DIN 43772
  • Extension neck to protect the head transmitter from overheating
  • Fast response time with reduced/tapered tip form
  • Types of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), non-sparking (Ex nA)
  • Head transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™

Specifications

Measuring Principle

  • Thermocouple

Characteristic / Application

  • metric style
  • modular temperature assembly
  • universal range of application
  • suitable for hazardous areas
  • suitable for high process pressures
  • flanged process connection
  • with neck
  • incl. thermowell / protection tube (metal)

Thermowell / Protection Tube

  • bar stock (drilled)

Insert / Probe

  • mineral insulated (MI), flexible

Outer Diameter Protection Tube / Insert

  • 18.0 mm (0.71'')
  • 24.0 mm (0.94'')

Max. Immersion Length on Request

  • up to 30,000.00 mm (1,181.10'')

Material Protection Tube/ Thermowell

  • 1.0460 (A105)
  • 1.4571 (316Ti)
  • 1.7335 (13CrMo4-5; F-11)
  • Alloy C276 (2.4819)
  • Duplex SAF 2205 (1.4462)
  • Titan Gr2 (3.7035 )

Optional Coating

  • Not defined

Process Connection

  • weld in version
  • DN25 PN40 B1 (EN1092)
  • DN40 PN40 B1(EN1092)
  • DN50 PN40 B1 (EN1092)
  • ASME 1" 150 RF (B16.5)
  • ASME 1" 300 RF (B16.5)

Tip Shape

  • tapered

Surface Roughness Ra

  • 0.8 μm (31.5 μin.)

Operating Temperature

  • Type K: max. 1,100 °C (max. 2,012 °F)
  • Type J: max. 750 °C (max. 1,382 °F)

Max. Process Pressure (static)

  • at 20 °C: 400 bar (5,802 psi)

Accuracy

  • class 1 acc. to IEC 60584

Response Time

  • depending on configuration

Integration Head Transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - Approvals

  • ATEX Ex ia, Ex nA
  • IECEx Ex ia
  • NEPSI Ex ia
  • EAC Ex ia
  • UKCA Ex ia, Ex nA, Ex tc

Certification

  • Gost Metrology
  • SIL (transmitter only)
show more