TMR35 Compact Thermometer

Brand: Endress+Hauser

TMR35 Compact Thermometer

Brand: Endress+Hauser
Fundamental Fundamental

With cost efficiency, optimal use of space, reliable operation, easy commissioning and hygienic design the TMR35 fulfills all the requirements in the Food & Beverage as well as in the Life Science industries. A variety of hygienic process connections leads to a high flexibility.

The TMR35 compact thermometers are used to measure temperatures from -50 °C to +150 °C (-58 °F to +302 °F), or up to +200 °C (+392 °F) with neck. The most common installation locations are tanks and pipes. TMR35 with process connections for hygienic applications.

Features
  • Small, compact design made entirely of stainless steel
  • Extremely short response times
  • Highly accurate even with short insertion lengths
  • 4-wire, Pt100 or PC-programmable transmitter with 4 to 20 mA output
  • Configuration and visualization with ReadWin®2000 PC operating software, which is free of charge
  • Breakdown information in event of sensor break or sensor short-circuit, adjustable as per NAMUR NE43
  • Hygienic compatible design with 3-A marking and EHEDG certification;Marine approval

Specifications

Measuring Principle

  • Resistance Temperature Detector

Characteristic / Application

  • metric style
  • compact temperature probe
  • fast response time
  • hygienic design
  • hygienic process connection
  • with or without neck

Thermowell / Protection Tube

  • without (not intended to be used with thermowell)
  • to be used with thermowell
  • incl. Tee-/elbow thermowell

Insert / Probe

  • pipe version, isolated wires, not flexible

Outer Diameter Protection Tube / Insert

  • 3.0 mm (0.12'')
  • 6.0 mm (0.24'')

Max. Immersion Length on Request

  • up to 600.00 mm (23.62'')

Material Protection Tube/ Thermowell

  • 1.4404 (316L)

Process Connection

  • hygienic:
  • conical sealing system G1/2" (metal)
  • clamp connections acc. to ISO 2852 / DIN 32676
  • screwed pipe joint acc. to DIN 11851
  • Varivent

Tip Shape

  • straight

Surface Roughness Ra

  • 0.4 μm (16 μin.)
  • 0.8 μm (32 μin.)

Operating Temperature

  • PT 100: -50 °C ...200 °C (-58 °F ...392 °F)

Max. Process Pressure (static)

  • at 20 °C: 100 bar (1,450 psi)

Accuracy

  • class A acc. to IEC 60751

Response Time

  • t50 = 1 s
  • t90 = 2 s

Integration Head Transmitter

  • no (4…20mA Signal)

Certification

  • 3A
  • Marine approval
  • UL 3111-1
show more