The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. The sensor may be used direct contact without thermowell or where the application requires it, spring load inside of a separate thermowell. Flexible configuration possible.
- Fine Chemicals
- Petrochemical industry
- Power stations
- Environmental engineering
- Measuring range: –40 to 1 100 °C (–40 to 2 012 °F)
- Static pressure range up to 75 bar dependent on the used process connection
- Protection class: IP68
- Types of protection for use in hazardous locations: Intrinsic safety (Ex ia), flameproof (Ex d), non-sparking (Ex nA)
- High degree of insert compatibility and design as per DIN 43772
- High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths
- For plug-in/screw-in with sliding compression fitting
Specifications
Brand
Measuring Principle
- Thermocouple
Characteristic / Application
- metric style
- modular temperature assembly
- for heavy duty applications
- suitable for hazardous areas
- threaded process connection
- without neck
Thermowell / Protection Tube
- without (not intended to use with thermowell)
Insert / probe
- mineral insulated (MI), flexible
Outer Diameter Protection Tube / Insert
- 3.0 mm (0.12'')
- 6.0 mm (0.24'')
Max. Immersion Length on Request
- up to 30,000.00 mm (1,181.10'')
Material Protection Tube/ Thermowell
- 1.4404 (316L)
- Alloy 600 (2.4816)
Process Connection
- male thread: NPT1/2", NPT3/4"
- compression fitting: NPT1/2", NPT3/4"
Tip Shape
- straight
- tapered
Operating Temperature
- Type K: max. 1,100 °C (max. 2,012 °F)
- Type J: max. 800 °C (max. 1,472 °F)
Max. Process Pressure (static)
- at 20 °C: 80 bar (1,160 psi)
Accuracy
- class 1 acc. to IEC 60584
Response Time
- depending on configuration
- t50 = 3 s
- t90 = 7 s
Integration Head Transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - Approvals
- ATEX Ex ia, Ex d, Ex nA
- IECEx Ex ia, Ex d, Ex tD
- NEPSI Ex ia, Ex d
- EAC Ex ia, Ex d
- Explosion proof
Certification
- Gost Metrology
- SIL (transmitter only)