Brand: Endress+HauserThe Pt100 cable probe is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables the cable probe to detect rapid temperature changes fast and accurate.
The TH12 temperature sensors are RTD's designed for use in the process industry or factory automation type of environment. They are made up of a measurement probe with a RTD, insulation and sheath.
Among other applications the sensors can be used on:
- Heat exchangers
- Power & recovery areas
- Carbon regeneration furnaces
- Dryers
- Flue gas
- Compressor stations
- Process reactors
- High flexibility due to customized immersion length
- Fast response time with reduced/tapered tip form
- Simplified model structure: Competitively priced, offers great value. Easy to order and reorder
- Improved galvanic isolation on most devices (2 kV)
Specifications
Brand
Measuring Principle
- Resistance Temperature Detector
Characteristic / Application
- US style
- cable probe
- process connection as compression fitting
- without neck
Thermowell / Protection Tube
- without (not intended to be used with thermowell)
Insert / Probe
- mineral insulated (MI), flexible
- PTFE-insulated, rigid
Outer Diameter Protection Tube / Insert
- 1/8'' (3.18 mm)
- 3/16'' (4.76 mm)
- 1/4'' (6.35 mm)
- 3/8'' (9.53 mm)
Max. Immersion Length on Request
- up to 96" (2439 mm)
- others on request
Material Protection Tube/ Thermowell
- Sensor sheath
- 316/316L
Optional Coating
- Not applicable
Process Connection
- Compression fitting: NPT1/8", NPT1/4"
Tip Shape
- straight
- reduced
Surface Roughness Ra
- Not defined
Operating Temperature
- PT100 WW: -200 °C … 600 °C (-328 °F … 1.112 °F)
- PT100 TF: -50 °C … 200 °C (-58 °F … 392 °F)
Max. Process Pressure (static)
- at 20 °C: 40 bar (580 psi)
- depends on configuration
Accuracy
- class A acc. to IEC 60751
- class B acc. to IEC 60751
Response Time
- 63% rt = 2.0 s
Integration Head Transmitter