Proline Promag H 300 Electromagnetic Flowmeter

Brand: Endress+Hauser

Proline Promag H 300 Electromagnetic Flowmeter

Brand: Endress+Hauser
Extended Extended
Heartbeat Technology Heartbeat Technology

Promag H is the preferred sensor for hygienic applications with highest requirements in the food and beverage and life sciences industries. With its compact transmitter Promag H 300 offers a high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables compliance and process safety at all times.

  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
  • Dedicated to demanding applications in the food and beverage as well as in life sciences industries

Device properties

  • Liner made of PFA
  • Sensor housing made of stainless steel (3A, EHEDG)
  • Wetted materials CIP, SIP cleanable
  • Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
Features
  • Flexible installation concept – numerous hygienic process connections
  • Energy-saving flow measurement – no pressure loss due to cross-section constriction
  • Maintenance-free – no moving parts
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology

Specifications

Measuring Principle

  • Electromagnetic

Product Headline

  • Specialist for hygienic applications with a compact, easily accessible transmitter
  • Dedicated to demanding applications in the food and beverage as well as in life sciences industries

Sensor Features

  • Flexible installation concept – numerous hygienic process connections
  • Energy‐saving flow measurement – no pressure loss due to cross section constriction
  • Maintenance‐free – no moving parts
  • Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG)

Transmitter Features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology
  • Wetted materials CIP, SIP cleanable. Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access

Nominal Diameter Range

  • DN 2 to 150 (1/12 to 6")

Wetted Materials

  • Liner: PFA
  • Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
  • Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
  • Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
  • Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum

Measured Variables

  • Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected conductivity

Max. Measurement Error

  • Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
  • Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s)

Measuring Range

  • 0.06 dm³/min to 600 m³/h (0.015 gal/min to 2 650 gal/min)

Max. Process Pressure

  • PN 40, Class 150, 20K

Medium Temperature Range

  • –20 to +150 °C (–4 to +302 °F)

Ambient Temperature

  • –40 to +60 °C (–40 to +140 °F)

Sensor Housing Material

  • 1.4301 (304), corrosion resistant

Transmitter Housing Material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

Degree of Protection

  • IP66/67, type 4X enclosure
  • IP69

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Inputs

  • Status input
  • 4-20 mA input

Digital Communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power Supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous Area Approvals

  • ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC

Product Safety

  • CE, C-tick, EAC marking

Functional Safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Marine Spprovals and Certificates

  • LR approval, DNV approval, ABS approval, BV approval

Pressure Approvals and Certificates

  • PED, CRN

Material Certificates

  • 3.1 material

Hygienic Approvals and Certificates

  • Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP
show more