Radiometric Level And Density Measurement Gammapilot FMG50
Brand: Endress+HauserRadiometric Level And Density Measurement Gammapilot FMG50
Brand: Endress+Hauser

The Gammapilot FMG50 compact transmitter is designed for non-contact point level detection, continuous level, interface and density measurement in liquids, solids, suspensions or sludges. As the first true 2-wire loop powered compact transmitter it minimizes engineering and installation efforts.
- For all kinds of process vessels, like reactors, autoclaves, separators, acid tanks, cyclones
- For liquids, solids, suspensions or sludges etc.
- Extreme measuring conditions, for example corrosion, abrasion, viscosity, toxicity
- Process temperature: No limitation (non-invasive)
- Process pressure: No limitation (non-invasive)
- Housing material: 316L, aluminum
- International explosion protection certificates, SIL, overfill prevention WHG
- First real 2-wire loop-powered compact transmitter minimizes engineering and installation efforts
- Reduced installation and engineering costs thanks to the first 2-wire loop powered compact transmitter
- Increased plant safety, efficiency and availability even under extreme process and ambient conditions
- Designed according to IEC 61508 with SIL2/3 approval for all measuring tasks
- Reduced verification effort and minimized plant shut-downs due to state-of-art Heartbeat Technology
- Usage in up to +80°C (+176°F) ambient temperature without additional cooling thanks to innovative sensor technology
- Bluetooth® wireless technology for remote operation out of the radiation beam
Specifications
Brand
Measuring Principle
- Radiometric
Characteristic / Application
- Compact transmitter for extreme process conditions (temperature, pressure)
- Non-contact measuring technique
Interface Measurement
- Interfaces liquid / liquid also with emulsion layers
- Interfaces liquid / solid
Specialities
- Heartbeat Technology
- SIL 2/3 according to IEC 61508
- Bluetooth® commissioning, operation and maintenance with the SmartBlue App
Supply / Communication
- 2-wire loop powered
Accuracy
- +/- 1%
Ambient Temperature
- -40 °C...+80 °C (-40 °F...+176 °F)
Process Temperature
- Any
Process Pressure / Max. Overpressure Limit
- Any
Main Wetted Parts
- Non-contact
Process Connection
- Non-contact
Sensor Length
- PVT scintillator
- 400 mm...3000 mm
- >3000 mm cascade mode
Max. Measurement Distance
- Unlimited measuring range
- Cascade
Communication
- 4...20 mA HART
Certificates / Approvals
- ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
Safety Approvals
- Overfill protection WHG
- SIL 2/3
Design Approvals
- EN 10204-3.1
Options
- Display
Components
- Isotope: FSG60, FSG61
- Source container: FQG60, FQG61, FQG62, FQG63, FQG66
- Mounting accessories: FHG61